Greenheck DOAS Service Training

Training Goals Become familiar with DOAS Equipment Understand key system components, including energy recovery wheels, controls, and electrical schematics, to improve installation, operation, and troubleshooting processes. Develop a basic understanding of DOAS Controls Learn how to navigate the Carel c.pCO controller, how to effectively use live trending over its web UI, alarm snapshots, and BMS compatibility with BACnet or Modbus. Know how to perform a proper start-up of the equipment Participants will go over the tools required, pre-start checks, and everything else to properly start-up DOAS equipment – ending with a hands-on start up on operable equipment. Confidently Troubleshoot and Maintain DOAS equipment We’ll review tech support and field technician expectations, as well as how to troubleshoot, maintain, and service equipment to solve problems for customers in the field with confidence. Agenda Introduction & Service Policies DOAS Electrical Schematics Energy Wheel Repair / Maintenance VFD Overview Controls Overview DOAS Web UI Start Up / Controls Prerequisites Basic understanding of HVAC systems and controls. Ability to read and understand blueprints and wiring diagrams. HVAC Tech

LG MLV-01 Multi V™ Installation Essentials

About the LG VRF Training Center TMS Johnson’s LG VRF Training Center offers hands-on education designed for contractors, engineers, and building owners.  From installation to commissioning and service, courses prepare trainees with knowledge and experience to make their LG VRF project a success. A variety of LG certifications are available, with the opportunity to interact with fully operational equipment with the guidance of an experienced instructor. Dry Contact 2 Points/Economizer, Model PDRYCB400 Dry Contact 2 Points/Economizer, Model PDRYCB400 Dry Contact for Thermostat, Model PDRYCB300 Dry Contact for Thermostat, Model PDRYCB300 Dry Contact for Thermostat, Model PDRYCB300 I/O Module, Model PEXPMB000 PRCTILO Commissioning and Troubleshooting Software Premium Remote Thermostat, Model PREMTA00 Simple Dry Contact, Model PDRYCB100 Simple Dry Contact, Model PDRYCB100 Simple Thermostat, Model PREMTC00U Thermostat, Model CRC Series VM3 Multi-Site Controller, Model PBACNBTR0A ZIGBEE Occupied Sensor Ceiling, Model ZVRCZOC1 ZIGBEE Occupied Wall Sensor, Model ZVRCZWOC1 1-Way Ceiling Cassette, Model ARNU073TUC4 2-Way Ceiling Cassette, Model ARNU183TLC4 3rd Party AHU Kit with VTS Air Handler 4-Way Ceiling Cassette – 2ft x 2ft Chassis, Model ARNU093TRC4 4-Way Ceiling Cassette – 3ft x 3ft Chassis, Model ARNU243TMA4 Art Cool

LG MLV-03 Multi V™ Advanced Service & Troubleshooting

About the LG VRF Training Center TMS Johnson’s LG VRF Training Center offers hands-on education designed for contractors, engineers, and building owners.  From installation to commissioning and service, courses prepare trainees with knowledge and experience to make their LG VRF project a success. A variety of LG certifications are available, with the opportunity to interact with fully operational equipment with the guidance of an experienced instructor. Dry Contact 2 Points/Economizer, Model PDRYCB400 Dry Contact 2 Points/Economizer, Model PDRYCB400 Dry Contact for Thermostat, Model PDRYCB300 Dry Contact for Thermostat, Model PDRYCB300 Dry Contact for Thermostat, Model PDRYCB300 I/O Module, Model PEXPMB000 PRCTILO Commissioning and Troubleshooting Software Premium Remote Thermostat, Model PREMTA00 Simple Dry Contact, Model PDRYCB100 Simple Dry Contact, Model PDRYCB100 Simple Thermostat, Model PREMTC00U Thermostat, Model CRC Series VM3 Multi-Site Controller, Model PBACNBTR0A ZIGBEE Occupied Sensor Ceiling, Model ZVRCZOC1 ZIGBEE Occupied Wall Sensor, Model ZVRCZWOC1 1-Way Ceiling Cassette, Model ARNU073TUC4 2-Way Ceiling Cassette, Model ARNU183TLC4 3rd Party AHU Kit with VTS Air Handler 4-Way Ceiling Cassette – 2ft x 2ft Chassis, Model ARNU093TRC4 4-Way Ceiling Cassette – 3ft x 3ft Chassis, Model ARNU243TMA4 Art Cool

Antec Critical Controls Training

About the Critical Controls Training Lab This facility offers a hands-on training environment with top of the line products for Lab, Pharmacy, and Patient Room applications, closely modeled after Antec’s training facilities in Winnipeg Canada. The training center is more than a chance to interact with the industry’s best fume hoods, valves, and monitors up close - it provides a hub for engineers, contractors and owners to immerse themselves in as much training they want, and leave with the confidence to design, operate, and maintain their systems. Aircuity IAQ Monitoring & Demand Control Ventilation System Antec CAVA Touchscreen Fume hood Controller Antec SVS Sidewall Velocity Sensor Antec SPS Sash Position Sensor Antec FPS Fume Hood Pressure Sensor Antec PMT Touchscreen Room Pressure Monitor Antec CURVE Cloud-based Monitoring Software Antec VV Insulated Venturi Valves Antec VFX Insulated Venturi FX Valve Price SDV Terminal Unit Price CARES Critical Area Recirculation/Exhaust System Price FFU, UFFU Fan Filter Unit Price PURAFLO Fan Filter Unit Kewaunee Supreme Air Venturi Fume Hood Price HGWC Hospital Grade Welded Ceiling System Nederman FX2 Fume Extraction Arm Demonstration Topics

Greenheck Make-Up Air Service Training

Training Goals Become familiar with TAP Direct Fired Equipment Students will familiarize themselves with circuits and schematics, troubleshooting, tips and more in the classroom and on real equipment. Develop a basic understanding of TAP controls We'll cover current and legacy controls package offerings, controller sequences, BMS setup/wiring, and wrap things up with interactive demonstrations. Know how to perform a proper start-up of the equipment Participants will go over the tools required, ladder diagrams, pre-start checks, and everything else to properly start-up direct gas equipment - ending with a hands-on start up on a Make-Up Air Unit. Be able to answer some of our most common calls We'll review tech support and field technician expectations, as well as how to troubleshoot, maintain, and service equipment to solve problems for customers in the field with confidence. Schedule Introduction (20 Minutes) Ladder Diagram Presentation (30 Minutes) Controls Presentation with hands-on training modules (60 Minutes) Break (20 Minutes) Direct Gas Start-Up Presentation and Video (30 Minutes) Hands-On Start-Up on Make Up Air (60 Minutes) Wrap-Up (20 Minutes) Prerequisites

Price Ultrasuite® + Climate Demo

About the Ultrasuite® + Climate Demonstration Lab The Ultrasuite® + Climate Demonstration Lab gives professionals who design, build, utilize, and oversee hospital operating rooms an opportunity to address the top concerns of their facilities through hands-on demonstration, with custom topics available by request. Operating room plenums with/without LED lighting. Laminar flow diffusers. Welded ceilings with/without integrated unistrut. Ceiling access panels with multiple ceiling designs. Ultrasuite® + Climate operating room system with integrated lighting. Venturi FX Air Valves and associated room pressure controls integrated into the operating room controls. Complete operating control including pressure, temperature, humidity, lighting, filter loading available via a single BACnet user interface. Demonstration Topics Temperature Balance A top request among surgical staff is to maintain low operating room temperatures for optimal concentration. Combined with perioperative hypothermia and its affect on patient outcomes, this presents a significant challenge. We'll demonstrate how a balance is made possible through its design, ASHREA standards, and CFD verified performance. Lighting Shadows and glare within the surgical zone were top concerns expressed by surgical staff in